Proportional Control
Cetop 3 |
Pressure max. P/A/B |
Pressure max. T |
Regulated Flow Rates |
Current max. |
NG 6 |
350 bar |
250 bar |
3 / 10 / 15 / 20 / 25 lpm |
2.35 Amps |
XD.3.A…/XD.3.C…series valves are used for controlling fluid direction and flow rate...
|
Cetop 3 |
Pressure max. P/A/B |
Pressure max. T |
Regulated Flow Rates |
Current max. |
NG 6 |
350 bar |
250 bar |
8 / 15 / 25 / 40 lpm |
2.35 Amps |
The open loop valves of series XDP….control the direction and the volume of the flow...
|
Cetop 5 |
Pressure max. P/A/B |
Pressure max. T |
Regulated Flow Rates |
Current max. |
NG 10 |
320 bar |
250 bar |
40 / 60 / 100 lpm |
2.5 Amps |
The open loop valves of series XDP control the direction and the volume of the flow according to...
|
Cetop 3 |
Pressure max. P/A/B |
Pressure max. T |
Regulated Flow Rates |
Current max. |
NG 6 |
350 bar |
210 bar |
8 / 15 / 25 / 40 lpm |
1.76 Amps |
The valves XDC series 2 control the direction and the volume of the flow according to the feeding...
|
Cetop 3 |
Pressure max. P/A/B |
Pressure max. T |
Regulated Flow Rates |
Commands |
NG 6 |
350 bar |
210 bar |
4 / 8 / 15 / 25 / 36 lpm |
Voltage or current signal |
The proportional directional valves XECV are designed as direct operated components for subplate...
|
Cetop 3 |
Pressure max. P/A/B |
Pressure max. T |
Regulated Flow Rates |
Commands |
NG 6 |
350 bar |
210 bar |
4 / 8 / 15 / 25 / 36 lpm |
Voltage or current signal |
The proportional directional valves XEPV are designed as direct operated components for subplate...
|
Cetop 3 |
Pressure max. |
Flow max. |
Δp Adjustment |
Ways |
Weight |
NG 6 |
350 bar |
25 lpm |
4 bar or 8 bar |
2V=2ways / 3V=3ways |
1.4 kgs |
The 2 or 3 way pressure regulator type AM.3.H. ensure the constant set flow rate in the presence...
|
Cetop 5 |
Pressure max. |
Flow max. |
Δp Adjustment |
Ways |
Weight |
NG 10 |
350 bar |
2V -65 lpm / 3V-70 lpm |
8 bar |
2V=2ways / 3V=3ways |
2.7kgs |
The 2 or 3 way pressure regulator type AM.5.H. ensures a constant set flow rate in the presence...
|
Cetop 3 |
Pressure max. A/B -P blocked |
Pressure max. T |
Regulated Flow Rates |
Current max. |
NG 6 |
315 bar |
250 bar |
5 / 10 / 16 / 28 lpm |
2.35 Amps |
This is a proportional valve where both the flow rate and pressure control flow functions have...
|
Cetop 3 |
Pressure max. A/B/P -T blocked |
|
Regulated Flow Rates |
Current max. |
NG 6 |
250 bar |
|
6 / 12 / 22 / 32 / 40 lpm |
2.35 Amps |
The open loop proportional flow regulator is 2 and 3 way compensated with priority function. It...
|
Cetop 5 |
Pressure max. A/B/P |
|
Regulated Flow Rates |
Current max. |
NG 10 |
250 bar |
|
45 / 75 / 105 lpm |
2.5 Amps |
The open loop proportional flow regulator is 2 and 3 way compensated with priority function. It...
|
Cetop 3 |
Pressure max. |
Flow max. |
Flow min. |
Weight |
NG 6 |
320 bar |
30 lpm |
2 lpm |
0.8 kgs |
Modular valve type AM.3.XMP.. used together with the pressure proportional pilot type...
|
Showing records 1 to 12 of 13
Dana SAC Ireland Ltd
Dana Incorporated, Allenwood Enterprise Park, Allenwood, Naas, Kildare, W91A4CP, Ireland.
Phone: +353-45-890100
Email:
© 2019 Dana SAC Ireland Ltd
By continuing to use this site you consent to the use of cookies in accordance with our cookie policy
d479601c73ad61980f205f0ca188c99f1894b2505cac828ac9c8caf6b72746d1