Highlights

  • Max. Operating Pressure 350 Bar
  • Max. Pressure Port T 250 Bar
  • Nominal Flow 8/15/25/40 L/min

The open loop valves of series XDP….control the direction and the volume of the flow according to the feeding current to the proportional solenoid. By using a valve body equipped with increased passage channels it is possible to reach the highest capacity of its dimensions at a parity of pressure drops, (40 l/min with delta pressure of 10 bar) Each delta pressure variation on the valve leads to the variation of the capacity which has been set, anyway the valve guarantees a high inner compensation grade and limits the adjustment capacity. Performances shown in the technical sheet in the download area, are guaranteed only using 2 or 3 way modular assembly hydrostats type AM.3.H… By using the valve with the base for capacity doubling type BC.3.07 a greater capacity can be obtained.

application/pdf XDP.3.pdf (160.88 KB)